Stx f set form stop position (backfeed command), Stx g print last label format – Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 33

System-Level Command Functions
Class Series Programmer’s Manual
19
STX f
Set Form Stop Position (Backfeed Command)
This sets the stop position of the printed label, allowing the label to stop at a point past the start-of-
print position. When the next label format is sent, the printer motor reverses direction to retract the
media to the start-of-print position. If quantities of more than one label are requested, the printer will
operate without backfeeding. A backfeed will then only occur when printing has stopped for a few
seconds.
Non-Display Models: The printer Option Control must be set (via the menu) to ‘Host’ for this
command to have effect.
Display-Equipped Models: This command is not honored, see
Syntax:
Where:
nnn
- Is a three-digit distance from the Media Sensor, in inches/100 or
mm/10. This distance is independent of the start-of-print position
(
), yet it must be greater than the start-of-print position to
take effect.
Sample:
The sample sets a stop position distance of 230 (2.3 inches from the Media Sensor’s eye).
STX G
Print Last Label Format
This command prints a previously formatted label and restarts a canceled batch job following the last
processed label. This is used when there is a label format in the buffer. The
used to enter the quantity. (If the
Syntax: