Datamax-O'Neil Class Series Programmer’s Manual User Manual
Page 258

Appendix L – Speed Ranges
Class Series Programmer’s Manual
244
Print Speed
Feed Speed
Reverse Speed
Slew Speed (GPIO)
Model
Range
Default
Range
Default
Range
Default
Range
Default
A-4212
C – W
O
C – W
O
C – I
G
C – a
O
A-4310
C – S
O
C – W
O
C – I
G
C – a
O
A-4408
C – O
K
C – S
K
C – I
G
C – a
K
A-4606
C – K
G
C – O
G
C – I
G
C – a
G
A-6212
C – W
O
C – W
O
C – I
G
C – Y
O
A-6310
C – S
O
C – W
O
C – I
G
C – Y
O
E-4203
[1]
A – G
G
A – G
G
A – E
C
N/A
N/A
E-4204
A – G
G
A – G
G
A – E
C
N/A
N/A
E-4304
A – G
G
A – G
G
A – E
C
N/A
N/A
EX2
A – G
G
A – G
G
A – E
C
N/A
N/A
H-4212 &
H-4212X
C – W
O
C – W
O
C – G
G
C – a
O
H-4310 &
H-4310X
C – S
O
C – W
O
C – G
G
C – a
O
H-4408
C – O
K
C – S
K
C – G
G
C – a
K
H-4606 &
H-4606X
C – K
G
C – O
G
C – G
G
C – a
G
H-6210
C – S
K
C – W
K
C – G
G
C – W
K
H-6212X
C – W
O
C – W
O
C – G
G
C – Y
O
H-6308
C – O
K
C – S
K
C – G
G
C – S
K
H-6310X
C – S
O
C – W
O
C – G
G
C – Y
O
H-8308X
C – O
K
C – S
K
C – G
G
C – W
K
I-4206
C – K
K
C – O
K
C – G
G
C – K
K
I-4208
C – O
O
C – O
O
C – G
G
C – O
O
I-4210
C – S
O
C – S
O
C – G
G
C – W
O
I-4212
C – W
O
C – W
O
C – G
G
C – W
O
I-4308
C – O
K
C – O
K
C – G
G
C – O
K
I-4406
C – K
I
C – K
I
C – G
G
C – K
I
I-4604
C – G
E
C – G
E
C – G
G
C – G
E
M-4206
C – K
G
C – K
G
C – G
C
C – K
G
M-4208
C – O
O
C – O
O
C – G
G
C – O
O
M-4306
C – K
G
C – K
G
C – G
C
C – K
G
S-Class
3210 series
C - K
G
C - K
G
C - I
E
N/A
N/A
S-Class
3306 series
C - S
K
F -S
K
C - I
E
N/A
N/A
W-6208
C – O
K
C – S
K
C – G
G
C – S
K
W-6308
C – O
K
C – S
K
C – G
G
C – S
K
W-8306
C – K
K
C – O
K
C – G
G
C – O
K
[1]
Maximum speed is limited to ‘E’ unless the optional regulated power supply is attached.
Table L-2: Speed Ranges and Defaults