background image

Configuration of the camera

Guppy PRO Technical Manual V4.0.0

209

420h + 000002h x 4 = 428h

The entry with key D1 in the root directory (424h in this case) provides the
offset for the unit directory as follows:

424h + 000004 x 4 = 434h

The entry with key D4 in the unit directory (440h in this case) provides the
offset for unit dependent info:

440h + 0000xx * 4 = 444h

To compute the effective start address of the node unique ID leaf

currAddr

= node unique ID leaf address

destAddr

= address of directory entry

addrOffset

= value of directory entry

destAddr

= currAddr + (4 x addrOffset)

= 420h + (4 x 000002h)

= 428h

Table 105: Computing effective start address

Offset

0-7

8-15

16-23

24-31

428h

00

02

5E

9E

....

CRC

Node unique ID leaf

42Ch

00

0A

47

01

….

Node_Vendor_Id

,

Chip_id_hi

430h

00

00

Serial number

Table 106: Configuration ROM

Offset

0-7

8-15

16-23

24-31

Unit directory

434h

00

03

93

7D

438h

12

00

A0

2D

43Ch

13

00

01

02

440h

D4

00

00

01

Table 107: Configuration ROM