Trigger modes, E chapter, E trigger mode 1 in chapter – ALLIED Vision Technologies Guppy PRO F-503 User Manual
Page 143

Controlling image capture
Guppy PRO Technical Manual V4.0.0
141
Trigger modes
Guppy PRO cameras support IIDC conforming Trigger_Mode_0 and
Trigger_Mode_1 and special Trigger_Mode_15 (bulk trigger).
Note
CMOS cameras Guppy PRO F-503 support only
Trigger_Mode_0.
Trigger mode
also known as
Description
Trigger_Mode_0
Edge mode
Sets the shutter time according to the value set in
the shutter (or extended shutter) register
Trigger_Mode_1
Level mode
Sets the shutter time according to the active low
time of the pulse applied (or active high time in
the case of an inverting input)
Trigger_Mode_15
Programmable mode
Is a bulk trigger, combining one external trigger
event with continuous or one-shot or multi-shot
internal trigger
Table 54: Trigger modes