beautypg.com

Atec Agilent-PNA-X Series User Manual

Page 16

background image

16

Table 6. N4691B 2-Port Electronic Calibration Module

Description

Specification (dB)

10 MHz to

50 MHz

50 MHz to

500 MHz

500 MHz to

2 GHz

2 GHz to

8.5 GHz

8.5 GHz to

13.5 GHz

13.5 GHz to

20 GHz

20 GHz to

26.5 GHz

Directivity

46

46

52

46

46

46

44

Source
Match

41

41

47

42

42

42

40

Load Match

40

40

46

41

41

40

38

Reflection Tracking

Mag

±0.050

±0.050

±0.020

±0.040

±0.040

±0.040

±0.050

Phase (°)

±0.330

±0.330

±0.132

±0.264

±0.264

±0.264

±0.330

Transmission Tracking without Option 029

Mag

±0.062

±0.056

±0.023

±0.054

±0.054

±0.055

±0.072

Phase (°)

±0.410

±0.370

±0.152

±0.354

±0.354

±0.365

±0.473

S

21

Transmission Tracking with Option 029

1

Mag

±0.065

±0.060

±0.028

±0.063

±0.063

±0.063

±0.079

Phase (°)

±0.431

±0.394

±0.183

±0.416

±0.416

±0.416

±0.521

S

12

Transmission Tracking with Option 029

1

Mag

±0.085

±0.068

±0.029

±0.061

±0.061

±0.064

±0.078

Phase (°)

±0.559

±0.446

±0.193

±0.400

±0.400

±0.421

±0.517

The port 1 noise tuner switch set to the bypass position, and port 2 noise receiver switch set to the normal position.