beautypg.com

E8361c – Atec Agilent-E8364C User Manual

Page 26

background image

26

E8361C

Corrected system performance with 1.85 mm connectors

continued

Description Specification

(dB)

20 to 35 GHz

35 to 50 GHz

50 to 60 GHz

60 to 67 GHz

Directivity 37 37 34 34
Source match

41

42

40

40

Load match

36

36

33

33

Reflection tracking

±0.033 (+0.02/°C)

±0.020 (+0.02/°C)

±0.030 (+0.02/°C)

±0.030 (+0.03/°C)

Transmission tracking

±0.097 (+0.02/°C)

±0.091 (+0.02/°C)

±0.140 (+0.02/°C)

±0.145 (+0.03/°C)

Transmission uncertainty (specifications)

Reflection uncertainty (specifications)

Magnitude

0.01

0.1

1

10

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

10

Transmission coefficient (dB)

E8361C full two port cal using 85058B (Exp math)

20 to 35 GHz
35 to 50 GHz

50 to 60 GHz

60 to 67 GHz

S11 = S22 = 0
Source power = -15 dBm

Uncertainty (dB)

Phase

0.1

1

10

100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

10

Transmission coefficient (dB)

E8361C full two port cal using 85058B (Exp Math)

20 to 35 GHz
35 to 50 GHz
50 to 60 GHz
60 to 67 GHz

S11 = S22 = 0
Source power = -15 dBm

Uncertainty (degrees)

Magnitude

0

0.01

0.02

0.03

0.04

0.05

0

0.2

0.4

0.6

0.8

1

Reflection coefficient (linear)

E8361C with 85058B (Exp math)

20 to 35 GHz
35 to 50 GHz
50 to 60 GHz
60 to 67 GHz

S21 = S12 = 0
Source power = -15 dBm

Uncertainty (linear)

Phase

0

2

4

6

8

10

0

0.2

0.4

0.6

0.8

1

Reflection coefficient (linear)

E8361C with 85058B (Exp math)

20 to 35 GHz
35 to 50 GHz
50 to 60 GHz
60 to 67 GHz

S21 = S12 = 0
Source power = -15 dBm

Uncertainty (deg)

Standard configuration and standard power range
(E8361C)
Applies to E8361C PNA Series analyzer,
85058B (1.85 mm) calibration kit, N4697F flexible
test port cable set, and a full two-port calibration.
(Specifications apply over environmental tempera-
ture of 23 °C ±3 °C, with less than 1 °C deviation
from calibration temperature.)