Remote Control, cont’d

PIP 422 and PIP 444 Picture-in-Picture Processors • Remote Control

4-8

Command/response table for SIS commands (cont’d)

Command

ASCII Command

Response

Additional description

(host to PIP)

(PIP to host)

Front panel lockout (Executive mode)

Lock front panel

1X

Exe1

Lock front panel picture control
and menu system adjustments,
RS-232/422 adjustments only.

Unlock front panel

0X

Exe0

All adjustments and selections
can be made from the front panel.

View front panel lock status

X

X2

Show executive mode status.

Zap (reset to default settings)

Total reset

Esc

zXXX

ZapXXX

“z” must be lower case, “XXX”
must capitalized. Reset all
settings and adjustments to the
factory defaults.

Reset all presets

Esc

ZG

Zpg

Clear all presets and their names.

Reset individual preset

Esc

ZG

X14

Zpg

X14

Clear preset

X14

.

Query firmware version

General

Q

X16

Show the controller firmware
version.

All firmware

0Q

X16

,

X16

,

X16

,

X16

Show the firmware versions for
all partitions.

Specific firmware

X17

Q

X16

Show the firmware version for
partition

X17

.

View build number

+Q

X16

.

X19

Show the firmware build
number.

Request part number

Request part number

N

60-607 (606)-01

Show the PIP’s part number.

Request information

View all inputs’ video standards

I

X18

,

X18

,

X18

,

X18

Display each input’s video
standard. The video standards
are automatically detected; you
cannot change these entries.

View a specific input’s

X1

i

X18

Display the input video standard

video standard

for input

X1

. The video standard

is automatically detected; you
cannot change this entry.

Unsolicited report

None

Std

X1

*

X18

Display the input video standard
for input

X1

in response to a

change in input signal.

Show temperature

20S

X20

F•

X21

C

Show the PIP’s temperature in
degrees Fahrenheit and Celsius.

The show temperature (20S) command is only available on newer model PIPs.