beautypg.com

Unit reset, Selecting the baud rate and rs-232/rs-422 protocol, Operation, cont’d – Extron Electronics PIP 444 User Guide User Manual

Page 34: Figure 3-15 — system reset flowchart

background image

Operation, cont’d

PIP 422 and PIP 444 Picture-in-Picture Processors • Operation

3-16

Unit reset

To reset the PIP to its factory default settings, press and hold the Menu and Next
buttons while you power up the processor (figure 3-15). The LCD panel displays
the message System Reset for two seconds and then begins the default display
cycle.

Press and hold both buttons

simultaneously while applying power.

The front panel reset also returns the
firmware to the factory default.

NOTE

10 sec.

Power

MENU

NEXT

2 sec.

2 sec.

SYSTEM RESET

Default

Cycle

60-606 (607)

-01

FW ver. n.nn

Extron, Inc.

PIP 444 (422)

Figure 3-15 — System reset flowchart

Selecting the baud rate and RS-232/RS-422 protocol

The processor can operate at 9600, 19200, 38400, and 115200 baud rates and support
either RS-232 or RS-422 serial communication protocol. The settings of these
variables can be viewed and changed from the front panel.

View and configure the switcher’s serial communications settings as follows:

1

.

To enter Serial Port Configuration mode, simultaneously press and hold the
Freeze button and Preset button while you apply power to the processor
(figure 3-16). The processor’s LCD displays the baud rate upon completion of
the power up process.

Press and hold both buttons

simultaneously while applying power.

20 sec.

Power

Baud Rate

9600

FREEZE

WINDOW PRESET

PRESET

NEXT

Baud rate selection

• 9600 (default)
• 19200
• 38400
• 115200

NEXT

Port Type

RS-232

Port selection

• RS-232 (default)
• RS-422

Default

Cycle

Figure 3-16 — RS-232/RS-422 and baud rate selection

This manual is related to the following products: