Extron Electronics MTPX Plus Series User Guide User Manual
Page 98

Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests (continued)
Request system status
S
See below
MTPX Plus 128:
X3$
•
X3$
•
X3$
•
X3$
•
X3$
•
X3%
•
X3^
•
X3^
•
X3^]
Other matrix sizes 1616 and smaller:
X3$
•
X3$
•
X3$
•
X3$
•
X3$
•
X3%
•
X3^
•
X3^]
Matrix sizes 1632 and larger:
X3$
•
X3$
•
X3$
•
X3$
•
X3$
•
X3$
•
X3$
•
X3%
•
X3^
•
X3^
•
X3^]
Response description (MTPX Plus 128):
+3.3V•+5V•-5V•+12V•-12V•
temperature
(degrees
Fahrenheit)
•
Fan
1
speed
•
Fan
2
•
Fan
3
]
Response description (other matrix sizes 1616 and smaller):
+3.3V•+5V•-5V•+12V•-12V•
temperature
(degrees
Fahrenheit)
•
Fan
1
speed
•
Fan
2
]
Response description (matrix sizes 1632 and larger):
+3.3V•+5V•-5V•+12V•-12V•+2.5V•-2.5V•
temperature
(degrees
Fahrenheit)
•
Fan
1
speed
•
Fan
2
•
Fan
3
]
NOTE
:
Fans are numbered 1, 2, 3, from rear to front.
Example (MTPX Plus 128):
S
Fan 1 (rear) rotating at 3590 RPM
+3.3V power system at 3.28V
+12V power system at 11.52V
+3.28•+4.98•-5.01•+11.52•-12.35•+086.80•03590•03668•03668
NOTE:
X3$
= Voltage
Positive or negative voltage and magnitude
X3%
= Temperature
Degrees Fahrenheit
X3^
= Fan speed
RPM
MTPX Plus Series • Programming Guide
92