beautypg.com

Programmer’s guide, cont’d – Extron Electronics Fiber Matrix 6400 User Manual

Page 78

background image

Programmer’s Guide, cont’d

Fiber Matrix 6400 Switcher • Programmer’s Guide

4-14

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

Names

Write global preset name

EX&,X1)

NG

}

Nmg

X&,X1)]

Example:

E

1,Security 1NG

}

Nmg01

,

Security 1

]

Name global preset 1
“Security 1”.

Read global preset name

EX&

NG

}

X1)]

Example:

E

2NG

}

Security 2

]

Global preset 2 is named
“Security 2”.

Write room name

EX*,X1)

NR

}

Nmr

X*,X1)]

Example:

E

1

,

Classrm 1NR

}

Nmr01

,

Classrm 1

]

Name room 1 “Classrm 1”.

Read room name

EX*

NR

}

X1)]

Write room preset name

EX*

*

X(,X1)

NP

}

Nmp

X*

*

X(,X1)]

Example:

E

1*3

,

Podium_DVDNP

}

Nmp01*3

,

Podium_DVD

]

Name room1, preset 3
“Podium_DVD”.

Read room preset name

EX*,X(

NP

}

X1)]

N

• Do not use leading spaces in preset names.

If a preset is unassigned, the

X1)

displays

[unassigned].

If a global preset is saved, but not yet named, the default name is Preset

X&

.

If a room preset is saved, but not yet named, the default name is Rm

X*

Prst

X(

.

Write input name

EX!,X1)

NI

}

Nmi

X!,X1)]

Example:

E

1

,

Podium camNI

}

Nmi01

,

Podium cam

]

Name input 1 “Podium cam”.

Read input name

EX!

NI

}

X1)]

Write output name

EX#,X1)

NO

}

Nmo

X#,X1)]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1”.

Read output name

EX#

NO

}

X1)]

Front panel lockout (Executive mode)

Lock front panel

1X

Exe1

]

Enable executive mode.

Unlock front panel

0X

Exe0

]

Disable executive mode.

View lock status

X

X1#]

N

X!

= Input number

01 – 64

X#

= Output number

01 – 64

X&

= Global preset #

00 – 32 (00 = current configuration)

X*

= Room # (for room presets)

10 max. (Each can have up to 10 presets (

X(

) assigned.)

X(

= Room preset #

00 - 10 (00 = current configuration for room)

X1)

= Name

12 characters maximum for global and room preset names

11 characters maximum for room names

X1#

= Lock mode

0 = unlocked

1 = locked