Host-to-switcher instructions, Switcher-initiated messages, Programmer’s guide, cont’d – Extron Electronics Fiber Matrix 6400 User Manual
Page 70

Programmer’s Guide, cont’d
Fiber Matrix 6400 Switcher • Programmer’s Guide
4-6
Host-to-Switcher Instructions
The switcher accepts SIS (Simple Instruction Set) commands through either serial
port and the LAN port. SIS commands consist of one or more characters per
command field. They do not require any special characters to begin or end the
command character sequence. Each switcher response to an SIS command ends
with a carriage return and a line feed (CR/LF =
]
), which signals the end of the
response character string. A string is one or more characters.
Switcher-Initiated Messages
When a local event such as a front panel operation occurs, the switcher responds
by sending a message to the host. The switcher-initiated messages are listed below
(underlined).
(c) Copyright 2007, Extron Electronics, Fiber Matrix 6400, Vx.xx, 60-878-01{day,
date, time}]
The switcher initiates the copyright message when it is first powered on or when
connection via Internet protocol (IP) is established. Vx.xx is the firmware version
number.
N
{Day, date, time} are only reported if the connection is via the LAN port.
]Password:
The switcher initiates the password message immediately after the copyright
message when the controlling system is connected using TCP/IP or telnet and the
switcher is password protected. This message means that the switcher requires an
administrator or user level password before it will perform the commands entered
via this link. The switcher repeats the password message response for every entry
other than a valid password until a valid password is entered.
]
Login Administrator
]
]
Login User
]
The switcher initiates the login message when a correct administrator or user
password has been entered. If the user and administrator passwords are the same,
the switcher defaults to administrator privileges.
Qik
]
The switcher initiates the Qik message when a front panel switching operation has
occurred.
Sprnn
]
The switcher initiates the Spr message when a memory preset has been saved from
the front panel. nn is the preset number.
Rprnn
]
The switcher initiates the Rpr message when a memory preset has been recalled
from the front panel. nn is the preset number.
Vmtnn*x
]
The switcher initiates the Vmt message when a channel output mute is toggled
on or off from the front panel. nn is the output number and x is the mute status:
1 = on, 0 = off.
Exen
]
The switcher initiates the Exe message when executive mode is toggled on or off
from the front panel. n is the executive mode status: 1 = on, 0 = off.