beautypg.com

Programmer’s guide, cont’d – Extron Electronics Fiber Matrix 6400 User Manual

Page 74

background image

Programmer’s Guide, cont’d

Fiber Matrix 6400 Switcher • Programmer’s Guide

4-10

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

Output re-clocking

Set output re-clocker

X#

*

X%

=

Rte

X#

*

X%]

Set the re-clocker rate for
output

X#

to

X%

.

Example:

8*00=

Rte08*00

Set the re-clocker for output
8 to auto.

Read re-clocker status

X#

=

Rte

X#

*

X%]

Show current re-clocker rate

X%

for output

X#

.

I/O Grouping

N

The group that is assigned in each of the following I/O grouping commands (

X^

) must be 1, 2, 3, 4, or 0 (not grouped).

Write input grouping

EX^

1

X^

2

...

X^

n

I

}

Gri

X^

1

X^

2

X^

3

...

X^

n

]

Each

X^

entry is the group

number assigned to an
input position, starting from
input 1. n is the highest-
numbered input.

Example (16 x 16 matrix):

E

40133000044...4I

}

See below.

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10

15 16

4 0 1 3 3 0 0 0 0 4

4 4

11 12 13 14

0 0 0 4

Input 2 not grouped

Input 16 in group 4

Input 1 - Group 4, Input 2 -
Group 0 (not grouped), ...
Input 16 - Group 4.

Write output grouping

EX^

1

X^

2

...

X^

12

O

}

Gro

X^

1

X^

2

X^

3

...

X^

n

]

Each

X^

entry is the group

number assigned to an output
position, starting from output 1.
n

is the highest-numbered

output.

Read input grouping

E

I

}

X^

1

X^

2

X^

3

...

X^

n

]

Each

X^

entry is the group

number assigned to an input
position, starting from input 1.
n

is the highest-numbered

input.

Example (8 x 8 matrix):

E

I

}

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08

1 1 1 3 3 0 0 0

Input 8 not grouped

Read output grouping

E

O

}

X^

1

X^

2

X^

3

...

X^

n

]

Each

X^

entry is the group

number assigned to an
output position, starting
from output 1. n is the
highest-numbered output.

N

X#

= Output number

01 – 64

X%

= Output re-clocking rate

00 = auto (default)

01 = bypass

X^

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)