Performing a system reset from the front panel

The front panel reset is identical to the

E

ZXXX

}

SIS command (see chapter 4,

“Programmer’s Guide”). A system reset clears all ties and presets, all output mutes,

and resets all I/O grouping.
Reset the switcher to the factory default settings by pressing and holding the

View button and Esc button while you apply AC power to the switcher.

N

You must apply power from an unpowered state. Applying the redundant power

with primary power already applied does not reset the switcher.

System reset does not reset the Internet protocol (IP) settings or replace user-
installed firmware.

100-240V 50/60H

z

1.2A MAX.

100-240V 50/60H

z

1.2A MAX.

REDUND

ANT

PRIMAR

Y

LIN

A

TX

LINK

1

RX

LINK

2

B

TX

LIN

K

A

TX

LINK

1

RX

LINK

2

B

TX

LINK

1

RX

LINK

2

C

TX

LINK

1

ANAHEIM, CA

PRIMAR

Y PO

WER SUPP

LY

41 - 4

8

49 - 56

57 - 64

CONTROL

T

VIEW

ESC

Press and hold the View and Esc
buttons while you apply power to
the switcher.

Release the View and Esc buttons.

Power

The switcher flashes the
button indicators; light amber,
off, green, red, and amber;
and then turns them off.

Continue to hold the View and Esc
buttons until all input and output buttons
return to either unlit or to background
illumination.

Background illumination

The buttons on the front panel can be set to provide amber background

illumination at all times or the background illumination can be turned off. To

toggle the background illumination on or off, press and hold the Input 1 and

Input 2 buttons simultaneously for approximately 2 seconds.

1

2

3

17 18 19 32

16

Press and hold the Input 1 and Input 2 buttons
simultaneously for approximately 2 seconds to
toggle background illumination mode on or off.

Release the Input 1 and Input 2 buttons.