beautypg.com

Extron Electronics Fiber Matrix 6400 User Manual

Page 75

background image

4-11

Fiber Matrix 6400 Switcher • Programmer’s Guide

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

Save, recall, and directly write presets

N

• If you try to recall a preset that is not saved, the matrix switcher responds with the error code

E11.

If a room is not defined (does not exist in the switcher), the matrix switcher responds with the error code

E21.

The following characters are invalid in preset names:

+ - , ` @ = [ ] { } ‘ “ ; : | \ and ?.

Save current configuration
as a global preset

X&,

Spr

X&]

Command character is a
comma.

Example:

9

,

Spr09

]

Save current ties as preset 9.

Recall a global preset

X&.

Rpr

X&]

Command character is a
period.

Example:

5

.

Rpr05

]

Recall preset 5, which
becomes the current
configuration.

Save current ties as a room
preset

X*

*

X(,

Rmm

X*•

Spr

X(]

Command character is a
comma.

Example:

3*9,

Rmm03

Spr09

]

Save current ties as preset 9
for room 3.

Direct write process —

N

The

direct write of a global preset should always be preceded by a clear global preset ties command of that same

preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied input) remains
unchanged unless overwritten or cleared.

If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that
are part of the previous version of the specified preset with the same number can unexpectedly become part of the newly-
created preset.

Clear a global preset’s ties

E

+

X&

P0*!

}

Spr

X&]

Clear all ties in preset

X&

.

Directly write a global preset

E

+

X&

P

X@

*

X#

!

X@

*

X#

%

X@

*

X#

$ ...

X@

*

X#

%

}

Enter as many ties as are
valid for this configuration.
The ! tie command, & tie,
and % tie commands are all
valid.

Spr

X&]

Example:

E

+27P0*!

}

Spr27

]

Clear all ties in preset 27.

+27P12*5!10*09%3*2!3*8&

Esc

Brackets are shown to separate
ties for clarity only. Create
global preset 27, which ties
input 12 to output 5, input 10
to output 9, input 3 to output
2, and input 3 to output 8.

Spr27

]

Write room outputs

EX*,X#

1

,X#

2

,

...

X#

n

MR

}

See notes.

Mpr

X*

,

X#

1

,X#

2

,

...

X#

n

]

N

• A room can contain a maximum of 16 outputs.

An output can belong to only one room.

The maximum number of rooms (

X*

) is 10.

If no room name is assigned, the default name is “Room #

X*

X#

1

,•

X#

2

,•

X#

3

”.

Example:

E

8

,

3

,

04

,

5

,

6MR

}

Mpr08

,

03

,

04

,

05

,

06

]

Outputs 3, 4, 5, and 6 are
assigned to room 8.

N

X@

= Input number

00 – 64 (00 = untied)

X#

= Output number

01 – 64

X&

= Global preset #

00 – 32 (00 = current configuration)

X*

= Room # (for room presets)

10 max. (Each can have up to 10 presets (

X(

) assigned.)

X(

= Room preset #

00 – 10 (00 = current configuration for room)