beautypg.com

Extron Electronics Fiber Matrix 6400 User Manual

Page 25

background image

2-9

Fiber Matrix 6400 Switcher • Installation

N

This port is independent of the rear panel Remote port and is not affected by

changes to the rear panel port’s protocol. This front panel port’s protocol can be
changed under SIS command control only. See the Command/Response table for
IP-specific SIS commands, in chapter 4, “Programmer’s Guide”,
to configure all
ports under SIS control.

N

Both the front panel Configuration port connection and the rear panel Remote

port connection can be active at the same time.

This port is RS-232 only, with its default protocols as follows:
• 9600 baud

• no parity

• 8 data bits

• 1 stop bit

• no flow control

N

The maximum distances from the matrix switcher to the controlling device

can vary up to 200 feet (61 m). Factors such as cable gauge, baud rates,
environment, and output levels (from the switcher and the controlling device)
all affect transmission distance. Distances of about 50 feet (15 m) are typically
not a problem. In some cases the matrix switcher may be capable of serial
communications via RS-232 up to 250 feet (76 m) away.