beautypg.com

Symbol definitions, Symbol definitions -8, Programmer’s guide, cont’d – Extron Electronics Fiber Matrix 6400 User Manual

Page 72

background image

Programmer’s Guide, cont’d

Fiber Matrix 6400 Switcher • Programmer’s Guide

4-8

Symbol definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D)

= Space character

E

= Escape key (hex 1B))

X!

= Input number

01 – 64

X@

= Input number (for tie)

00 – 64 (00 = untied)

X#

= Output number

01 – 64

X$

= Mute

0 = not muted, 1 = muted

X%

= Output re-clocking rate

00 = auto (default)

01 = bypass

X^

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X&

= Global preset #

00 – 64 maximum (00 = current configuration)

X*

= Room # (for room presets)

10 max. (each can have up to 10 presets (

X(

) assigned)

N

A Room is a subset of operator-selected outputs that relate to each other. The Fiber Matrix switcher supports up to 10 rooms, each of

which can consist of from 1 to 16 outputs.

X(

= Room preset #

10 maximum (0 = current configuration for room)

N

A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory,

it becomes the current configuration.

X1)

= Name

12 characters maximum for input names, output names, global preset

names, and room preset names

11 characters maximum for room names

Upper- and lower-case alphanumeric characters and

_ / and spaces are valid.

N

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1!

= Connection status

0 = no input connected

1 = input connected

X1@

= Output rate:

nnnn

= actual rate (in MHz)

0000 = no connection or rate mismatch

- - - - = bypass mode

X1#

= Lock mode, power supply

0 = unlocked/not OK

1 = locked/OK

X1$

= Number (quantity) of inputs

8, 16, 24, 32, 40, 48, 56, or 64

X1%

= Number (quantity) of outputs

8, 16, 24, 32, 40, 48, 56, or 64

X1^

= Board installed

0 = No board installed

1 = 8x8 multimode board

2 = 8x8 singlemode board

3 = SDI/HD-SDI board

x = Unknown board or mix of transceivers installed

X1&

= I/O board slot number

1 – 8

X1*

= Fiber optic transceiver module installed

0 = No module installed

1 = Multimode module

2 = Singlemode module

3 = SDI-HD-SDI board (all I/Os on board)

X1(

= Firmware version number to second decimal place (x.xx)

X2)

= Verbose firmware version-description-upload date/time.

See the Query firmware version (verbose) command on page 4-16.

X2!

= Voltage

Positive or negative voltage and magnitude

X2@

= Temperature

Degrees Fahrenheit

X2#

= Fan speed (in RPM)