beautypg.com

Maintenance and modifications, Location a, Location h – Extron Electronics Fiber Matrix 6400 User Manual

Page 122: Slot 1, O#1 i#1 slot 2, Slot 3, Slot 4

background image

Fiber Matrix 6400 Switcher • Maintenance and Modifications

7-2

Maintenance and Modifications

Removing and Installing the I/O Board or Blank Panel

W

The Fiber Matrix 6400 fiber optic I/O boards output continuous invisible
light, which may be harmful and dangerous to the eyes; use with caution.

Do not look into the rear panel fiber optic cable connectors or into the

fiber optic cables themselves.

Plug the attached dust caps into the optical transceivers when the fiber

optic cable is unplugged.

N

As factory configured, the fiber optic I/O boards are configured as either

100 percent singlemode or 100 percent multimode, but you can remove a fiber
optic transceiver module (one input and one output) of one transmission mode
and replace it with a block of the other transmission mode.

You can mix transmission mode transceiver modules on a fiber optic I/O board,
provided that you ensure that each fiber cable and connected devices are the
appropriate transmission mode for the transceiver module.

Typically, singlemode fiber has a yellow jacket and multimode cable has an
orange jacket.

N

Unlike the FOX 500 transmitters and receivers, which output an optical

stream on one connector in a block and receive a return optical stream on the
second connector in the same block, the fiber optic I/O board uses one connector
on the block as an input and the second connector on the same block as a separate
output.

N

For proper cooling and air flow, boards and/or blank panels should be installed in

all locations during normal switcher operations.

Circuit boards can be replaced for fault correction or to accommodate SDI/HD-SDI

(electric) signals. They can be added or removed to increase or decrease the I/O

configuration (size) of the Fiber Matrix.
See figure 7-1. Each I/O board is identified by the input and output numbers supported

by the board position (1 - 8, 9 - 16, and so on) The transceiver modules on fiber optic

I/O boards and the BNC connectors on SDI/HD-SDI boards are identified as A through H.

RESET

RS232/RS422

REMO

TE

LAN

A

CT

LINK

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

A

OUT

IN

B

OUT

IN

C

OUT

IN

D

OUT

IN

E

OUT

IN

F

OUT

IN

G

OUT

IN

H

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

Location A

Input

Location A

Output

Location H

Input

Location H

Output

Location H

Output and Input

Location A

Output and Input

Slot 1

(1-8)

O#1

I#1

Slot 2

(9-16)

Slot 3

No board

installed

Slot 4

(25-32)

O#2

I#2

O#3

I#3

O#4

I#4

O#9

I#25

I#26

I#27

I#28

I#29

I#30

I#31

I#32

O#25

O#26

O#27

O#28

O#29

O#30

O#31

O#32

I#9

O#10

I#10

O#11

I#11

O#12

I#12

O#5

I#5

O#6

I#6

O#7

I#7

O#8

I#8

O#13

I#13

O#14

I#14

O#15

I#15

O#16

I#16

A

H

H

H

A

A

Figure 7-1 — Arrangement of inputs and outputs on the I/O boards

Locations A through H correspond to the output and input numbers identified

by the board position numbers. (For example, the output and input numbers

supported by the I/O board in location 9 - 16 are as follows: A = 9, B = 10, C = 11,

D = 12, E = 13, F = 14, G = 15, and H = 16.)