Command and response table for basic sis commands, Command and response table for, Basic sis commands – Extron Electronics DMP 64 User Guide User Manual
Page 104

Command and Response Table for Basic SIS Commands
Command
ASCII command
(host to device)
URL Encoded
(web)
Response
(device to host)
Information requests
Firmware Version
Q
*Q
X1!]
Firmware and build version
*Q
*Q
X1!]
Kernel firmware and build
**Q
**Q
X1!]
Verbose version info
0Q
0Q
Sum of 2Q-3Q-4Q
]
Firmware version
1Q
1Q
X1!]
Bootstrap Version
2Q
2Q
X1!]
Factory Firmware Version
3Q
3Q
X1!
plus web ver.-desc-UL
date/time
]
Updated firmware version
4Q
4Q
X1!
plus web ver.-desc-UL
date/time
]
NOTE: An asterisk (*) after the version number indicates the currently running version. Question marks (?.??) indicate that
only factory firmware is loaded. A caret (^) indicates the firmware version that should be running, but a Mode 1 reset
was executed and the default factory firmware is running. An exclamation point (!) indicates corrupted firmware.
Query part number
N
N
60–1054-01
]
Query model name
I
I
V00x00•A06x04
]
Query model name
1I
1I
DMP•64
]
Query model description
2I
2I
Digital•Matrix•Processor
]
Query system memory
usage
3I
3I
#Bytes used out of
#KBytes
]
Query user-memory usage
4I
4I
#Bytes used out of
#KBytes
]
NOTE:
X1!
= Version number
Firmware version number to second decimal place (x.xx)
Version and Build number adds four digits (x.xx.xxxx)
to the Version number
DMP 64 • SIS Programming and Control
98