Command and Response Table for Basic SIS Commands
Command
ASCII command
(host to device)
URL Encoded
(web)
Response
(device to host)
Information requests
Firmware Version
Q
*Q
X1!]
Firmware and build version
*Q
*Q
X1!]
Kernel firmware and build
**Q
**Q
X1!]
Verbose version info
0Q
0Q
Sum of 2Q-3Q-4Q
]
Firmware version
1Q
1Q
X1!]
Bootstrap Version
2Q
2Q
X1!]
Factory Firmware Version
3Q
3Q
X1!
plus web ver.-desc-UL
date/time
]
Updated firmware version
4Q
4Q
X1!
plus web ver.-desc-UL
date/time
]
NOTE: An asterisk (*) after the version number indicates the currently running version. Question marks (?.??) indicate that
only factory firmware is loaded. A caret (^) indicates the firmware version that should be running, but a Mode 1 reset
was executed and the default factory firmware is running. An exclamation point (!) indicates corrupted firmware.
Query part number
N
N
60–1054-01
]
Query model name
I
I
V00x00•A06x04
]
Query model name
1I
1I
DMP•64
]
Query model description
2I
2I
Digital•Matrix•Processor
]
Query system memory
usage
3I
3I
#Bytes used out of
#KBytes
]
Query user-memory usage
4I
4I
#Bytes used out of
#KBytes
]
NOTE:
X1!
= Version number
Firmware version number to second decimal place (x.xx)
Version and Build number adds four digits (x.xx.xxxx)
to the Version number
DMP 64 • SIS Programming and Control