GE Industrial Solutions Entellisys 4.0 Integrator's Guide User Manual
Page 116
![background image](/manuals/294929/116/background.png)
Modbus Memory Map Format Codes
116
4
5
Invalid CRC check of node firmware
6
IButton
Missing
7
EEPROM
Configuration
Invalid
8
Not
Used
9
Not
Used
10
Not
Used
11
Not
Used
12
Not
Used
13
Not
Used
14
Not
Used
15
Not
Used
F702
BITFIELD
SRCx Node System Diagnostics 1
0
Node not receiving a broadcast message from CPU A
1
Node not receiving a broadcast message from CPU B
2
No link pulse from CPU A
3
No link pulse from CPU B
4
Invalid system frequency received from CPU A
5
Invalid system frequency received from CPU B
6
Invalid IOC pickup setting multiplier received from CPU A
7
Invalid IOC pickup setting multiplier received from CPU B
8
Invalid ST setting received from CPU A
9
Invalid ST setting received from CPU B
10
Invalid GF setting received from CPU A
11
Invalid GF setting received from CPU B
12
Invalid command received from CPU A
13
Invalid command received from CPU B
14
CPU A command not completed due to arbitration
15
CPU B command not completed due to arbitration
F703
BITFIELD
SRCx Node System Diagnostics 2
0
CPU A command timed out
1
CPU B command timed out
2
Node synch not locked
3
Unknown Message Received on Port 0
- EntelliGuard G Spring charge Contact (3 pages)
- Austin Lynx II SIP (19 pages)
- TLE Series 225-500 User Manual (90 pages)
- Power Mark Gold Generator Interlock Kit (2 pages)
- CAR2548FP series (15 pages)
- Spectra Series Power Panelboards AEG47 and AEG47S (1 page)
- GE TR7000 Series (17 pages)
- Record Plus Motor Operator Mechanism: FC100 (6 pages)
- Spectra Series Power Panelboards Endwall Kit (1 page)
- ProTrip Conversion Kits DB-75, DBL-75, DB-100, DBL-100 (16 pages)
- Spectra II Series Busway Plugs (2 pages)
- Spectra Series Power Panelboards AMC2GM and AMC3GM (2 pages)
- EntelliGuard 800–2000 A Frames, 240–600 Vac Maintenance Manual (64 pages)
- EntelliGuard G Ready To Close (4 pages)
- Position Switch Kit (12 pages)
- Spectra Series Power Panelboards AMCB4QD and AMCB6QD (4 pages)
- Record Plus TDR Door-Ring Interlock Kit: FC100 (4 pages)
- ProTrip Conversion Kits DB-15 (20 pages)
- Record Plus TDR, NEMA 1, 12: FE250 (5 pages)
- ATL010A0X43-SR (21 pages)
- Spectra Series Power Panelboards 30–200 Ampere Fusible Switch (2 pages)
- CAR2512FP Front-End (15 pages)
- CP2000AC54TE (20 pages)
- MX150_MX250 Modbus Network Card (27 pages)
- Spectra Series Power Panelboards 800 & 1200 Ampere Fusible Switch (2 pages)
- Spectra Series Fusible Switch Units J & T (4 pages)
- EntelliGuard G NETWORK INTERLOCK DEVICE (3 pages)
- EntelliGuard TU Trip Units (106 pages)
- ZBTSD Series (36 pages)
- AF-600 FP Profibus DP (91 pages)
- Neutral Mounting Kit - DNK400 (1 page)
- Record Plus Variable Depth Operating Mechanism: FE250 (4 pages)
- Spectra Series Power Panelboards 30–60 Ampere Expansion Kit (4 pages)
- Power Break II Undervoltage Release (4 pages)
- Record Plus Shunt Trip and Undervoltage Release (4 pages)
- EntelliGuard G Drawout Secondary Disconnect (4 pages)
- ACE4000T SERIES (2 pages)
- SPSA600 (12 pages)
- Dry-Type General Purpose Power Transformers (8 pages)
- Power Express Class 2 (8 pages)
- Austin MegaLynx (20 pages)
- CAR1612FP series (7 pages)
- H5692448 Power Systems Infinity M1 (NE-M) (76 pages)
- CAR2024FP series (7 pages)
- EBVW020A0B Barracuda Series (18 pages)