5.4 Drive Object Classes
Use the Drive classes for read and write of all AF-600 FP or AF-650 GP pa-
rameter values. For each parameter group a corresponding object Class is
defined. The following table shows the classes supported, and their relation-
ship to the AF-600 FPAF-650 GP or AF-600 FP parameters.
The class Instance and Attribute acts in the following way:
-
100 added to the parameter group = the value for the class
-
100 added to the remaining parameter number = the value for the instance
-
100 added to the array index of the parameter = the value for the attribute.
GE Classes
Parameter Group
Class
F-##
Class 100
E-##
Class 101
C-##
Class 102
P-##
Class 103
H-##
Class 104
K-##
Class 105
AN-##
Class 106
B-##
Class 107
O-##
Class 108
PB-##
Class 109
SP-##
Class 110
XC-##
Class 111
DR-##
Class 112
LG-##
Class 113
CL-##
Class 114
ID-##
Class 115
AP-##
Class 116
T-##
Class 117
FB-##
Class 118
PC-##
Class 119
AO-##
Class 120
BP-##
Class 121
DN-##
Class 122
PI-##
Class 123
LC-##
Class 124
EC-##
Class 125
RS-##
Class 126
BN-##
Class 127
LN-##
Class 128
EN-##
Class 129
CB-##
Class 130
CA-##
Class 131
CD-##
Class 132
NB!
Some parameter groups are only available in either the AF-650 Gp or AF-600 FP.