12 class id 0f4 parameter object, 13 class id 10h parameter group object – GE Industrial Solutions AF-650 GP DeviceNet User Manual
Page 33

5.3.12 Class ID 0F4 Parameter Object
This object is an interface to the parameters of the drive. It identifies configurable parameters and supplies their description, including min. and max. values and
a descriptive text.
The attributes supported are listed below.
Attribute
Access
Stub/Full
Name
Data type
Description
1
Set/Get
Stub
Parameter value
Data type
1
Actual value of parameter
2
Get
Stub
Link path size
USINT
Size of link path
3
Get
Stub
Link path
ARRAY
DeviceNet's path to parameter's origin
Segment type/port
BYTE
Segment Address
Path
4
Get
Stub
Descriptor
WORD
Description of parameter
5
Get
Stub
Data type
EPATH
Data type code
6
Get
Stub
Data size
USINT
Number of bytes in parameter value
7
Get
Full
Parameter name
string
SHORT
STRING
Human readable text string representing parameter name
8
Get
Full
Units string
SHORT
STRING
Human readable text string representing parameter name
9
Get/Set
Full
Help string
SHORT
STRING
Human readable text string representing parameter name
10
Get
Full
Min value
Data type
1
Min valid value
11
Get
Full
Max value
Data type
1
Max valid value
12
Get
Full
Default value
Data type
1
Parameters default value
13
Get
Full
Scaling multiplier
UINT
Multiplier for scaling factor
14
Get
Full
Scaling divisor
UINT
Divisor for scaling factor
15
Get
Full
Scaling base
UINT
Base for scaling formula
16
Get
Full
Scaling offset
INT
Offset for scaling formula
17
Get
Full
Multiplier link
UINT
Parameter instance of multiplier source
18
Get
Full
Divisor link
UINT
Parameter instance of divisor source
19
Get
Full
Base link
UINT
Parameter instance of base source
20
Get
Full
Offset link
UINT
Parameter instance of offset source
21
Get
Full
Decimal precision
USINT
Specifies parameter value format
1
= Same data type as the parameter.
5.3.13 Class ID 10h Parameter Group Object
This Object defines 14 parameter groups for all AF-600 FP and AF-650 GP parameters. One Class instance exists for each parameter group. A read out of an
instance will contain the name of the current parameter group.
Group
Instance
Name (max. 16 characters)
1
1
F
U
N
D
A
M
E
N
T
A
L
P
A
R
A
2
2
D
I
G
I
T
A
L
I
N
O
U
T
3
3
F
R
E
Q
U
E
N
C
Y
C
O
N
T
R
O
4
4
M
O
T
O
R
D
A
T
A
5
5
H
I
G
H
P
E
R
F
P
A
R
A
M
E
6
6
K
E
Y
P
A
D
S
E
T
U
P
7
7
A
N
A
L
O
G
I
N
O
U
T
8
8
B
R
A
K
I
N
G
F
U
N
C
T
I
O
N
9
9
O
P
T
I
O
N
S
C
O
M
M
S
10
10
S
P
E
C
I
A
L
F
U
N
C
T
I
O
N
11
11
C
A
N
F
I
E
L
D
B
U
S
12
12
P
I
D
C
O
N
T
R
O
L
S
AF-600FP /650 GP DeviceNet Operating Instructions
32
5