22 error number for drive profile v3.0 – GE Industrial Solutions AF-600 FP Profibus DP User Manual
Page 50

5.2.22 Error Number for Drive Profile V3.0
When the parameter request is invalid, the frequency converter will return a corresponding error code. The table below lists the full range of error codes.
Error codes for DP V1 parameter requests
Error code
Meaning
Additional Info
0x00
Unknown parameter
0
0x01
Parameter is read-only
sub-index
0x02
Value out of range due to max/min value
sub-index
0x03
Wrong sub-index
sub-index
0x04
Parameter is no array
0
0x05
Wrong data type (wrong data length)
0
0x06
This parameter may not be set, only reset
sub-index
0x07
Descriptive element is read-only
sub-index
0x09
No description available (only value)
0
0x0b
Process control not possible
0
0x0f
No text array available (only value)
0
0x11
Not possible in current state
0
0x14
Value out of range due to drive state/configuration
sub-index
0x15
Reply too long (more than 240 bytes)
0
0x16
Wrong parameter address (unknown or unsupported value for attribute, element, par. number or sub-
index or illegal combination)
0
0x17
Illegal format (for writing)
0
0x18
Value amount not consistent
0
0x65
Wrong axis: action not possible with this axis
-
0x66
Unknown service request
-
0x67
This service is not possible with multi parameter access
-
0x68
Parameter value can not be read from network
-