9 request / response attributes, 10 request reference, 11 request id – GE Industrial Solutions AF-600 FP Profibus DP User Manual
Page 46: 12 response id, 13 axis

5.2.9 Request / Response Attributes
The table contains an overview of the possible attributes of the PROFIdrive parameter channel.
Field
Data type
Values
Remark
Request reference
Unsigned8
0x01..0xFF
Request ID
Unsigned8
0x01
request parameter value
Identification for read or write request
0x02
change parameter value
0x42
change parameter non-volatile
0x51
request par. value double word
0x52
change par. value double word
Response ID
Unsigned8
0x01
request parameter (+) Positive
Identification for the response
0x02
change parameter (+) Positive
0x81
request parameter (-) Negative
0x82
change parameter (-) Negative
Axis
Unsigned8
0x00..0xFF
number (always 0)
Number of parameters Unsigned8
0x01..0x25
Limitation: DP V1 message length
Attribute
Unsigned8
0x10
value
0x20
description
Data description
0x30
text
Number of elements
Unsigned8
Limitation: DP V1 message length
0x01-0xFA
Quantity 1-234
Parameter number
Unsigned16
0x0001...
number 1-65535
Parameter number
0xFFFF
Subindex
Unsigned16
0x0000
number 0-65535
Array pointer
0xFFFF
Format
Unsigned8
See table
Number of values
Unsigned8
0x01..0xEA
Quantity 0-234
Limitation: DP V1 message length
Error number
Unsigned16
0x0000...
Error number
5.2.10 Request Reference
Unique identification of request/response pair for the master. The master changes the request reference with each new request. The slave mirrors the request
reference in the response.
5.2.11 Request ID
The following request identifications are defined:
0x01
Request parameter
0x02
Change parameter (Data are NOT stored in non-volatile memory, lost at power cycle)
0x42
Change parameter non-volatile (Data are stored in non-volatile memory)
0x51
Request parameter value double word. (All parameters are formatted and transferred as Double Word size, regardless of the actual data
type)
0x52
Change parameter value double word. (All parameters must be formatted and sent as Double Word size, regardless of data type)
5.2.12 Response ID
The Response ID indicates if the Read or Write request was successfully performed in the frequency converter. If the response is negative, the request is answered
negative (first bit = 1) and an error code is entered per partial response, instead of the value.
5.2.13 Axis
The axis attribute should be set to zero.
AF-650 GP/AF-600 FP Profibus DP Operating Instructions
45
5