Rainbow Electronics AT86RF211 User Manual
Page 37

37
AT86RF211
1942C–WIRE–06/02
•
WL1 Programming
WL1 can be set from 1 ms to 1.024
sec
. A 1 ms period clock is used for this delay
generation.
Bit 6 gives a period multiplication factor of 1 or 16 (by 16 clock prescaler).
Bits 5 to 0 give the number of cycles of the divided clock from 1 to 64 (counter).
Table 16. Wake Up Period Programming
WPER[8:0]
WPER[8:7]
WPER[6:0]
Period
Prescaler
Comments
(000)
16
(00)
2
(00)
16
10 ms
1
1 x 10 ms
(001)
16
(00)
2
(01)
16
20 ms
1
(1+1) x 10 ms
–
(00)
10
(vv)
10
–
1
(vv +1) x 10 ms
(07e)
16
(00)
2
(7e)
16
1270 ms
1
1 x 1270 ms
(07f)
16
(00)
2
(7f)
16
1280 ms
1
1 x 1280 ms
(101)
16
or (081)
16
(10)
2
or (01)
2
(01)
16
170 ms
16
((16 x 1)+1) x 10 ms
(102)
16
or (082)
16
(10)
2
or (01)
2
(02)
16
330 ms
16
((16 x 2)+1) x 10 ms
–
(10)
2
or (01)
2
(vv)
10
–
16
((16 x vv)+1) x 10 ms
(17e)
16
or (0fe)
16
(10)
2
or (01)
2
(7e)
16
20.2 sec
16
((16 x 126)+1) x 10 ms
(17f)
16
or (0ff)
16
(10)
2
or (01)
2
(7f)
16
20.3 sec
16
((16 x 127)+1) x 10 ms
(181)
16
(11)
2
(01)
16
2.57 sec
256
((256 x 1)+1) x 10 ms
(182)
16
(11)
2
(02)
16
5.13 sec
256
((256 x 2)+1) x10 ms
–
(11)
2
(vv)
10
–
256
((256 x vv) +1) x 10 ms
(1fe)
16
(11)
2
(7e)
16
323 sec
256
((256 x 126)+1) x 10 ms
(1ff)
16
(11)
2
(7f)
16
325 sec
256
((256 x 127)+1) x 10 ms
Table 17. WL1 Programming
WL1[6:0]
WL1[6]
WL1[5:0]
Period
Prescaler
Comments
(00)
16
0
(00)
16
1 ms
1
1 x 1 ms
(01)
16
0
(01)
16
2 ms
1
(1+1) x 1 ms
(vv)
10
0
(vv)
10
vv + 1 ms
1
1x (vv +1) ms
(3e)
16
0
(3e)
16
63 ms
1
1 x 63 ms
(3f)
16
0
(3f)
16
64 ms
1
1 x 64 ms
(40)
16
1
(00)
16
16 ms
16
16 x 1 ms
(41)
16
1
(01)
16
32 ms
16
16 x 2 ms
–
1
(vv)
10
–
16
16 x (vv +1) ms
(7e)
16
1
(3e)
16
1.008 sec
16
16 x 63 ms
(7f)
16
1
(3f)
16
1.024 sec
16
16 x 64 ms