Rainbow Electronics AT86RF211 User Manual
Page 27

27
AT86RF211
1942C–WIRE–06/02
Table 6. CTRL1 Detailed Description
Name
Number
of Bits
Comments
PDN
1
General power-down
0: power down mode; only the serial interface is active
1: AT86RF211 activated
reset value: 0
RXTX
1
Reception or transmission selection
0: Rx mode
1: Tx mode
reset value: 0
DATACLK
1
DATA clock recovery selection
0: no signal on DATACLK output pin
1: Clock recovery active: DATACLK activated
reset value: 0
TXLOCK
1
Transmission on PLL lock
0: transmission enabled, regardless of the PLL lock status
1: transmission only when the PLL is locked
reset value: 1
note: the PLL status is stored in the PLLL bit of the STATUS register
PAPDN
1
Power amplifier power down
0: Tx Power Amplifier power down mode
1: Tx Power Amplifier activated (only if PDN = 1)
reset value: 0
WUEN
1
Wake-up function enable
0: Wake-up function disabled, whatever the content of the wake-up control registers
1: Wake-up function activated, depending on the content of wake-up control registers
reset value: 0
LNAGSEL
1
LNA gain selection
0: maximum gain
1: minimum gain
reset value: 0
MVCC
1
RSSI or V
CC
power supply measurement selection
0: RSSI voltage measurement, value is stored in STAT register: MRSSI bits
1: V
CC
voltage measurement, value is stored in STAT register: MVCC bits
reset value: 0
TRSSI
6
RSSI value threshold
DATAMSG validated if RSSI
≥
TRSSI + HRSSI (high RSSI level)
DATAMSG inhibited if RSSI < TRSSI - HRSSI (low RSSI level)
reset value: (000000)
2
HRSSI
3
Value RSSI hysteresis
reset value: (000)
2
TXLVL
3
Tx PA output power selection
(000)
2
: minimum transmission level
(111)
2
: maximum transmission level
reset value: (000)
2
TXFS
1
Tx frequency selection
0: F0 & F1
1: F2 & F3
reset value: 0