beautypg.com

3 battery monitor, 4 temperature monitor, Battery monitor – Rainbow Electronics 71M6542G User Manual

Page 141: Temperature monitor, Table 99, Table 100. temperature monitor, 1 100 vbat bv

background image

v1.1

© 2008–2011 Teridian Semiconductor Corporation

141

6.4.3 Battery Monitor

Table 98: Battery Monitor Performance Specifications (TEMP_BAT= 1)

Parameter

Condition

Min

Typ

Max

Unit

BV: Battery Voltage
(definition)

MSN mode, TEMP_PWR = 1

BRN mode,
TEMP_PWR=TEMP_BSEL

𝐵𝑉 = 3.3𝑉 + (𝐵𝑆𝐸𝑁𝑆𝐸 − 142) ∙ 0.0246𝑉 + 𝑆𝑇𝐸𝑀𝑃

∙ 297𝜇𝑉

𝐵𝑉 = 3.291𝑉 + (𝐵𝑆𝐸𝑁𝑆𝐸 − 142) ∙ 0.0255𝑉 + 𝑆𝑇𝐸𝑀𝑃

∙ 328𝜇𝑉

V

Measurement Error

1

100

VBAT

BV

VBAT =

2.0 V
2.5 V
3.0 V
4.0 V

-7.5

-5
-3
-3

7.5

5
3
5

%

Input impedance in
continuous measurement,
MSN mode.
V(VBAT_RTC)/I(VBAT_RTC)

V3P3 = 3.3 V,
TEMP_BSEL = 0,
TEMP_PER = 111,
VBAT_RTC = 3.6 V,

1

M

Load applied with BCURR

IBAT(BCURR=1) - IBAT(BCURR=0)

V3P3 = 3.3 V

50

100

140

µA

6.4.4 Temperature Monitor

Table 99. Temperature Monitor

Parameter

Condition

Min

Typ

Max

Unit

Temperature Measurement
Equation

In MSN,

TEMP_PWR

=1:

𝑇𝑒𝑚𝑝 = 0.325 ∙ 𝑆𝑇𝐸𝑀𝑃 + 22

In BRN, TEMP_PWR

=

TEMP_BSEL:

𝑇𝑒𝑚𝑝 = 0.325 ∙ 𝑆𝑇𝐸𝑀𝑃 + 0.00218 ∙ 𝐵𝑆𝐸𝑁𝑆𝐸

2

− 0.609 ∙ 𝐵𝑆𝐸𝑁𝑆𝐸 + 64.4

°C

Temperature Error

T

A

=+22

°C

-2

+2

°C

VBAT_RTC charge per
measurement

TEMP_BSEL = 0,
TEMP_PWR=0,
SLP Mode,
VBAT_RTC = 3.6 V

16

µC

Duration of temperature
measurement after setting
TEMP_START
(see note 1)

TEMP_PWR

= 0,

TEMP_PER

= 7,

SLP Mode,
VBAT_RTC = 3.6 V
Force V3P3D = 1.0 V

15

60

ms

Notes:

1.

Guaranteed by design; not production tested.