beautypg.com

External reset, Brown-out detection, Atmega8515(l) – Rainbow Electronics ATmega8515L User Manual

Page 45

background image

45

ATmega8515(L)

2512A–AVR–04/02

External Reset

An External Reset is generated by a low level on the RESET pin. Reset pulses longer
than the minimum pulse width (see Table 18) will generate a reset, even if the clock is
not running. Shorter pulses are not guaranteed to generate a reset. When the applied
signal reaches the Reset Threshold Voltage – V

RST

– on its positive edge, the delay

counter starts the MCU after the Time-out period t

TOUT

has expired.

Figure 24. External Reset During Operation

Brown-out Detection

ATmega8515 has an On-chip Brown-out Detection (BOD) circuit for monitoring the V

CC

level during operation by comparing it to a fixed trigger level. The trigger level for the
BOD can be selected by the fuse BODLEVEL to be 2.7V (BODLEVEL unprogrammed),
or 4.0V (BODLEVEL programmed). The trigger level has a hysteresis to ensure spike
free Brown-out Detection. The hysteresis on the detection level should be interpreted as
V

BOT+

= V

BOT

+ V

HYST

/2 and V

BOT-

= V

BOT

- V

HYST

/2.

The BOD circuit can be enabled/disabled by the fuse BODEN. When the BOD is
enabled (BODEN programmed), and V

CC

decreases to a value below the trigger level

(V

BOT-

in Figure 25), the Brown-out Reset is immediately activated. When V

CC

increases

above the trigger level (V

BOT+

in Figure 25), the delay counter starts the MCU after the

time-out period t

TOUT

has expired.

The BOD circuit will only detect a drop in V

CC

if the voltage stays below the trigger level

for longer than t

BOD

given in Table 18.

Figure 25. Brown-out Reset During Operation

CC

V

CC

RESET

TIME-OUT

INTERNAL

RESET

V

BOT-

V

BOT+

t

TOUT