Configuration guidelines, Power supply and fuse, Replacing the fuse – 3Com TR User Manual

Page 31: Installing the slide-in modules, Configuration guidelines 2-3, Power supply and fuse 2-3, Replacing the fuse 2-3, Installing the slide-in modules 2-3

background image

Installing the Slide-in Modules

2-3

Configuration Guidelines

The cable topology rules for Token Ring are shown
below:

Power Supply and Fuse

The Switch 2000 TR automatically adjusts to the sup-
plied voltage. The fuse is suitable for either 90-110V
A.C. or 220-240V A.C. A spare fuse is provided in the
fuse drawer.

Replacing the Fuse

Refer to Figure 2-1 for the location of the fuse. When
necessary, replace the Switch 2000 TR fuse with a
fuse that has the following specifications:

250 volts — 4A Slo-Blo

1

Power down the Switch 2000 TR by removing the AC
power cord or the Redundant Power System cords.

2

Gently pry open the fuse holder cover with a small
flat-blade screwdriver.

Figure 2-1 Switch 2000 TR Fuse Location

3

Slide out the fuse holder drawer and remove the fuse.

4

Install the replacement fuse and close the fuse
drawer.

5

Re-insert the power cord and apply power.

Installing the Slide-in Modules

This section explains how to install the three optional
modules into a SuperStack II Switch 2000 TR device.
The modules are:

ATM

FDDI

TR-in-FE

Media

4 Mbps

16 Mbps

Category 3 UTP

660 ft/200m

330 ft/100m

Category 4, 5 UTP

1,320 ft/400m

660 ft/200m

Type 1 STP

2,000 ft/600m

1,000 ft/300m

Fuse location

AC connector