Dyna. filter, Dyna. flange, Dyna. phaser – Yamaha WC42260 User Manual
Page 318: Appendix a: parameter lists
318
Appendix A: Parameter Lists
DM2000—Owner’s Manual
DYNA. FILTER
Two input, two output dynamically controlled filter.
DYNA. FLANGE
Two input, two output dynamically controlled flanger.
DYNA. PHASER
Two input, two output dynamically controlled phaser.
Parameter
Range
Description
SOURCE
INPUT, MIDI
Control source: input signal or MIDI Note On velocity
SENSE
0–100
Sensitivity
DIR.
UP, DOWN
Upward or downward frequency change
DECAY
1
1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz), 3 ms–23.0 s (fs=88.2 kHz), 3 ms–21.1 s (fs=96 kHz)
Filter frequency change decay speed
TYPE
LPF, HPF, BPF
Filter type
OFFSET
0–100
Filter frequency offset
RESO.
0–20
Filter resonance
LEVEL
0–100
Output Level
Parameter
Range
Description
SOURCE
INPUT, MIDI
Control source: input signal or MIDI Note On velocity
SENSE
0–100
Sensitivity
DIR.
UP, DOWN
Upward or downward frequency change
DECAY
1
1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz), 3 ms–23.0 s (fs=88.2 kHz), 3 ms–21.1 s (fs=96 kHz)
Decay speed
OFFSET
0–100
Delay time offset
FB.GAIN
–99 to +99%
Feedback gain (plus values for normal-phase feedback, minus val-
ues for reverse-phase feedback)
LSH F
21.2 Hz–8.00 kHz
Low shelving filter frequency
LSH G
–12 to +12 dB
Low shelving filter gain
EQ F
100 Hz–8.00 kHz
EQ (peaking type) frequency
EQ G
–12 to +12 dB
EQ (peaking type) gain
EQ Q
10.0–0.10
EQ (peaking type) bandwidth
HSH F
50.0 Hz–16.0 kHz
High shelving filter frequency
HSH G
–12 to +12 dB
High shelving filter gain
Parameter
Range
Description
SOURCE
INPUT, MIDI
Control source: input signal or MIDI Note On velocity
SENSE
0–100
Sensitivity
DIR.
UP, DOWN
Upward or downward frequency change
DECAY
1
1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz), 3 ms–23.0 s (fs=88.2 kHz), 3 ms–21.1 s (fs=96 kHz)
Decay speed
OFFSET
0–100
Lowest phase-shifted frequency offset
FB.GAIN
–99 to +99%
Feedback gain (plus values for normal-phase feedback, minus val-
ues for reverse-phase feedback)
STAGE
2, 4, 6, 8, 10, 12, 14, 16
Number of phase shift stages
LSH F
21.2 Hz–8.00 kHz
Low shelving filter frequency
LSH G
–12 to +12 dB
Low shelving filter gain
HSH F
50.0 Hz–16.0 kHz
High shelving filter frequency
HSH G
–12 to +12 dB
High shelving filter gain