15–3
Modulation values
* w/st means with V.17 short training
Class 2 Command Set
The following Class 2 commands are supported and implemented per TIA
PN2388 (8/20/90).
Supported Commands (per TIA PN2388 8/20/90)
Value
Modulation
Speed
Requirements
3
V.21 ch. 2
300
required for FTH & FRH
+FTH and +FRH support value 3 (V.21 ch. 2 / 300 bps) only.
24
V.27ter
2400
required for FTM & FRM
48
V.27ter
4800
required for FTM & FRM
72
V.29
7200
required for FTM & FRM
73
V.17
7200
required for FTM & FRM
74
V.17 w/st
7200
required for FTM & FRM
96
V.29
9600
required for FTM & FRM
97
V.17
9600
required for FTM & FRM
98
V.17 w/st
9600
required for FTM & FRM
121
V.17
12000
required for FTM & FRM
122
V.17 w/st
12000
required for FTM & FRM
145
V.17
14400
required for FTM & FRM
146
V.17 w/st
14400
required for FTM & FRM
Command Syntax
Description
+
Executes a command or sets a parameter.
+
Reads permissible settings.
+
Reads the current setting.
Command
Value
Description
+FAA=n
Auto-answer mode parameter:
n=0
The DCE answers as set by +FCLASS.
n=1
The DCE answers and auto-determines the call
type.
+FBADLIN=
<
value
>
0-255
Bad line threshold (number of consecutive bad
lines for a bad page parameter):
Determines if the "Copy Quality OK" on the T.30
flow chart is met.
of 0 implies that error checking is disabled.