8–16
Remote configuration control:
S37 Bit-mapped register;
Default: 0
For remote configuration using the panel menu: (See
*W
ab
,
*R
ab
)
S38 Bit-mapped register, default: 0:
*. Remote digital loopback request must also be granted. (
AT&T4
).
Code
Bits
Bin.
Dec.
Description
(4,3,2)
Reserved.
*Wab
(1)
0
0
Writes from the local profile
a to the remote
profile
b.
*Rab
1
2
Reads from the remote profile
b to the local
profile
a.
*F1
(0)
0
0
Denies remote request for configuration.
*F0
1
1
*
Grants remote request for configuration.
Code
Bits
Dec.
Description
(7 to 4)
0 to 5
Local profile number.
(3 to 0)
0 to 5
Remote profile number.
Note:
0 through 3 are profiles 0 to 3, 4 is the current profile, and 5 is the
factory default (4 and 5 are read-only).
Note:
When using the LCD panel for remote configuration, set
S36b1
and
S37
first, then activate it in the DIAGNOSTIC menu.
Code
Bits
Bin.
Dec.
Description
(7, 6)
Reserved.
(5)
1
32
Disables MNP5 negotiation regardless of
error control setting.
(4)
0
0
Multi-Auto answer with fax answering ena-
bled. (Default)
1
16
Disables fax answering in Multi-Auto mode.
Hangs up if a fax call is received.