ZyXEL Communications 2864 User Manual
Page 122

9–12
*M1
Leased-line auto-handshake on answer mode.
*P0-15
Sets leased-line transmission power level, range from 0 dBm to
-15 dBm (Default = -9 dBm); range from -12 dBm to -27 dBm if
S35b3
is set. The maximum transmission power for Omni 288P
and 288S is -9dBm and -3dBm, respectively.
*Q0
No action to poor signal quality.
*Q1
Retrain action taken if signal quality is poor.
+
*Q2
Adaptive rate; auto fall-back or fall-forward. (Default)
*Q3
Disconnect for poor signal quality.
*Rab
Read remote profile b to local profile a:
a
= 0-3,
local user profile number.
b
= 0-3,
remote user profile number.
4,
remote active configuration.
5,
remote factory default.
+
*S0
Secondary channel disabled. (Default)
*S1
Secondary channel enabled.
*T
Displays last caller ID message.
*V
Views password table.
*Wab
Writes the local configuration profile
a
to remote user profile
b
and
resets the remote modem from that profile:
a
= 0-3,
local user profile number.
4,
local active configuration.
5,
local factory default settings.
b
= 0-3,
remote user profile number.
Note:
The command
*Rab
only works when the modem is on-line, inde-
pendent of the type of connection involved.
Note:
This command requires the supervisor password before execution.
Note:
The command
*Wab
only works when the modem is on-line inde-