8 sru card specifications, Sru card specifications -20 – Zhone Technologies 900 User Manual
Page 86

2-20
IMACS System Release 5.1.6
Data Cards
Model No.
Running Head
SRU Card Specifications
SRU Card
5. If necessary, also perform loopbacks and send test signals to the affected circuit from
the other end. In addition, you can perform end-to-end tests using a suitable data test
set at one or both ends of the circuit in conjunction with the loopback functions of the
SRU card at either end.
6. If the SRU card is determined to be faulty, replace it and return the faulty unit for repair
to the location specified by your distributor.
2.8
SRU Card Specifications
SRU Card (Models 822060 and 822160)
Number of Ports
10
Physical Interface
female 8-pin RJ-48
Electrical Interface
RS232C, ITU-T V.28
Operational Interface
DCE - Full Duplex
Interface Settings
Asynchronous, Synchronous, V.14
Sub-rate Framing Format
X.50, V.14, DS0-A, DS0-B with 5, 10, or 20 divisions per DS0
Sub-rate Time slot Number
1 through 20 depending on Sub-rate Framing Format
Synchronous Data
Format
Transparent
Transmit Clocking
Software selectable per port; internal or external
Speeds
2.4, 4.8, 9.6, 14.4, 19.2, 28.8 and 38.4 kbps
Asynchronous Data
Format
V.14 or proprietary
Stop Bits
Software selectable per port; 1 or 2
Data Bits
Software selectable per port; 5, 6, 7 or 8
Parity
Software selectable per port; none, odd, even, space or mark
Speeds
.3, 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 28.8 and 38.4 kbps
Signaling
DSR
Tied to DTR
CTS
Software selectable per port; on, off (tied to RTS)
CTS delay
Software selectable per port; immediate, 30, 60 or 100 ms
RLSD
Software selectable per port; permanently on, follows remote RTS (drop on receipt
of IDLE or CGA RED)
Diagnostics & Alarms
BERT
Integral
Direction
Toward DTE or toward Network
Data Patterns
Off, mark, space, 1:1, 1:7, 511, 2047 zeros
Loopbacks
Local
Toward DTE or toward Network
Remote - Generation
Inband, latching, DDS format at CSU, DSU or OCU-DP
Remote - Detection
Inband, latching and non-latching DDS Format for OCU Loop, CSU Loop and
DSU Loop. Optional automatic ten (10) minute timeout
Error Correction