Bri u*8 and bri-sc u*8 card main screen actions -6 – Zhone Technologies 900 User Manual
Page 120

5-6
IMACS System Release 5.1.6
Data Cards
Model No.
Running Head
BRI Card User Screens and Settings
BRI Card
Figure 5-4. Typical BRI U*8 and BRI-SC U*8 Card Main Screen
Table 5-1 lists the actions you can perform from the bottom line of this screen. To perform an
action, type the letter corresponding to the uppercase letter of the desired action. For example,
to save your option settings, press “s”. Table 5-2 lists the option settings and their default
values.
Table 5-1. BRI U*8 and BRI-SC U*8 Card Main Screen Actions
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e., performance and test data).
Copy
Copies the contents of the current column (except time slot) to the next column.
Useful if a user changes a lot of entries in one column and wants to repeat those
changes in subsequent columns.
conVert
The Conversion feature allows the B channels to be used with ADPCM
compression features.
Eoc
Embedded Operations Channel
Ntu
Network Terminating Unit programming. (not applicable to 8262).
Test
Initiates and monitors testing of all BRI card ports. See Test section.
Perf
Shows the performance statistics for the port highlighted. See the Performance
Monitoring section. Not implemented in S/T card.
Main
Returns to the main terminal screen. If changes are made to settings and not
saved, users will be prompted to save or lose changes.