14 bri card test screen – Zhone Technologies 900 User Manual
Page 150

5-36
IMACS System Release 5.1.6
Data Cards
Model No.
Running Head
BRI Card User Screens and Settings
BRI Card
RX FIFO ERR
This field indicates whether there is currently a FIFO buffering error on the receive end. The
options are yes and no. This option is not user-selectable.
TX FIFO ERR
This field indicates whether there is currently a FIFO buffering error on the transmitting end.
The options are yes and no. This option is not user-selectable.
HW CODE
This option depends on hardware and is not user-selectable.
LINE TR
The options for the line transceiver type are tp3410 (National Semiconductor chip) and st5411
(SGS-Thompson chip). This option is dependent on the hardware and is not user-selectable.
ASIC REV
This option depends on the hardware and is not user-selectable.
EPLD REV
This option depends on the hardware and is not user-selectable.
5.3.14 BRI Card Test Screen
Pressing “t” (Test) from the BRI Card Main Screen will bring up the screen shown in Figure
5-17 for the BRI-U*8 and BRI-SC U*8 cards, Figure 5-18 for the BRI-ST*8 card. From this
screen, you can create test situations between two BRI cards, or between a single card and data
test equipment at a remote site. Table 5-23 lists the actions you can perform from the bottom
line of this screen, and Table 5-25 lists the option settings controlled on this screen, along with
their default values.
Note:
The Test Screen is only a snap shot - the user must press “R”efresh to display current
information.