Zhone Technologies 6211-I3-xxx User Manual
Adsl2+ single port modem, Adsl2+ single port bridge/router with usb
ADSL2+ Single Port Modem
6211-I3-xxx
✓
Auto-connect feature will
automatically detect the
first usable PVC and
automatically detect
PPPoE, PPPoA, and Bridge
Protocol(with DHCP Server
available)
✓
Configurable as either a
Bridge or Router
✓
Filter traffic based on
Destination or Source IP
Address and MAC
Addresses
✓
Traffic Class Rules based
on Protocol, Source IP,
Source Port, Destination
IP, Destination Port,
802.1p
✓
Single Click DSL test - Tests
Ethernet connection and
ADSL Synchronization
along with ATM OAM F5
segment pings and
end-to-end pings.
✓
Configured through
easy-to-use web interface
✓
DELT - Integrated Loop
Testing for Line
troubleshooting
ADSL2+ Single Port Bridge/Router with USB
The 6200 ADSL2+ family of endpoints deliver the required performance
for multimedia applications at very competitive price points. The 6200
ADSL2+ endpoints, in compact form factor, have been successfully used
for residential, business, in-building deployments such as hotel/motel,
temporary housing, and dormitory-campus installations for high-speed
internet access (HSIA) and video-on-demand services.
The Zhone 6200 ADSL2+ endpoints are easily user-installed. The
embedded web-based user interface is designed to simplify ADSL
deployment. All products provide an Ethernet connection that is
auto-sensing, eliminating the worry about connection cable type
(straight-through vs crossover).
DELT or Dual End Loop Test, is a feature that is present the 6200 Family
of ADSL2+ CPEs. DELT is primarily used for reactive tests on a loop after
a modem has been deployed—either to help troubleshoot a line or to
capture a baseline of loop characteristics at the time of installation.
Because DELT is a dual-ended test, it requires equipment that supports
the DELT feature at both ends of the copper loop. While this prevents
DELT from being used on loops where no CPE has yet been deployed,
DELT in turn offers a deeper set of loop tests, and can provide very
valuable information on the condition of a copper loop.
Default settings make for a quick and easy installation that doesn't
require any configuration.
The modem, when operating in router mode, support DHCP
Server/Relay/Client, NAPT, as well as RIP, dynamic routing, port
forwarding, and static routing. For security, firewall functions including
PAP/CHAP authentication and IP filtering are supported.