1 introduction, 2 ds0-dp card description, 1 ds0-dp 4 card description (825460) – Zhone Technologies 900 User Manual
Page 109: 1 card jumper/switch settings, 2 installing the card, Introduction -1, Chapter 4 ds0-dp card

Data Cards
IMACS System Release 5.1.6
4-1
DS0-DP Card
Introduction
Chapter 4
DS0-DP Card
4.1
Introduction
This chapter provides installation, configuration, and troubleshooting information for the DS0
Dataport (DS0-DP) Card. This card is labeled as the DS0-DP 4 card on its faceplate ejector.
4.2
DS0-DP Card Description
4.2.1
DS0-DP 4 Card Description (825460)
The DS0-DP 4 Card Contradirectional/Codirectional Data Unit (DS0-DP/G.703) provides a
64 kbps interface to a DS0 time slot of a T1 or E1 network. Since the byte alignment of the 64
kbps data stream to the time slot is essential, the interface provides a 64 kbps bit clock and an
8 kHz byte clock in the DS0-DP mode.
Notice!
UL STATEMENT
OPERATION OF THIS INTERFACE IS LIMITED TO INTRA-BUILDING
CONNECTIONS ONLY
4.2.1.1
Card Jumper/Switch Settings
The DS0-DP 4 Card does not have any jumpers or switches on its mainboard.
4.2.1.2
Installing the Card
Install the DS0-DP 4 Card into any user card slot. These slots are U1 to U8 on the two-sided
chassis and front-loading chassis with power supplies on top, and P1 to P4 or W1 to W4 on
the front-loading chassis with power supplies on the side.