Zhone Technologies 900 User Manual
Page 36

1-24
IMACS System Release 5.1.6
Data Cards
Model No.
Running Head
HSU Card User Screens and Settings
HSU Card
Notes:
1. The following BERT settings are available only on the four-port HSU 530/35 Card:
ds0, ff, 7e, 32, 40, ocu-a, dsu-a, csul-a, and csu2a. These settings are not available on
the HSU-T V11 and HSU-T 35 Cards.
BERT
The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER)
on the selected HSU port. The patterns that can be selected are off, mark (1111), space (0000),
1:1 (1010 alternating), 1:7 (0100-0000), 511 (511 test pattern), qrss (quasi-random signal
source), and 2047 (2047 test pattern).
On the four-port HSU 530/35 Card, selecting the ds0 pattern will display another set of BERT
patterns. Additional non-latching loopback patterns are ff (1111-1111), 7e (0111-1110), 32
(0011-0010), 40 (0100-0000), ocu-a (ocu-alternating byte), csu-a (csu-alternating byte),
dsu-a (dsu-alternating byte), csu1a (csu–one repeater–alternating byte), and csu2a (csu–two
repeater–alternating byte). The results of the alternating patterns (ocu-a, csu-a, dsu-a, csu1a
and csu2a) appear in the Test Screen.
Also note that the Bit Error Rate Tester is supported on the HSU-T V11 and HSU-T 35 Cards
only if the port mode is set to dce in their Card Main Screens.
Parameter
User Options
Notes
Default
BERT
off mark space 1:1 1:7 511 qrss
2047 ds0 ff 7e 32 40 ocu-a csu-a
dsu-a csu1a csu2a
1
off
CTS
norm off on
norm
RLSD
norm off on
norm
DSR
norm off on
norm
SYNC
information only–no user options
BE
information only–no user options
ES
information only–no user options
SES
information only–no user options
OSS
information only–no user options
BER
information only–no user options
ELAP
information only–no user options
RTS
information only–no user options
DTR
information only–no user options
LB ST
information only–no user options