Ocu-dp card ocu-dp card user screens and settings – Zhone Technologies 900 User Manual
Page 103

Data Cards
IMACS System Release 5.1.6
3-15
OCU-DP Card
OCU-DP Card User Screens and Settings
Table 3-5 lists the actions you can perform from the Test Screen. These appear on the bottom
highlighted line of the screen. Table 3-6 lists the settings controlled on this screen along with
their possible and default values.
Table 3-5. Test Screen Actions
Table 3-6. Test Screen Option Settings and Defaults
BERT
The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER)
on the selected OCU-DP port. The patterns that can be selected are off, mark (all ones), space
(all zeros), 1:1 (1010), 1:7 (0100-0000), 511 (511 test pattern), 2047 (2047 test pattern) and
qrss (quasi-random pseudo signal).
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Since the data in this screen is not updated in real time, the Refresh
command is used to obtain the latest statistics.
insertErr
Allows you to manually insert a single error into a clear data signal.
Test
Clears the Test Screen.
Main
Returns to the OCU-DP Card Main Screen. If changes are made to settings
and not saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
BERT
off mark space 1:1 1:7 511 2047 qrss
off
DIR
net user
net
DATA
pri sec
pri
SYNC
information only–no user options
BE
information only–no user options
ES
information only–no user options
SES
information only–no user options
CSES
information only–no user options
OSS
information only–no user options
BER
information only–no user options
ELAP
information only–no user options
LB ST
information only–no user options
4W DDS
information only–no user options