2 bri-sc u*8 sealing current, Bri-sc u*8 sealing current -7, Bri card bri card user screens and settings – Zhone Technologies 900 User Manual
Page 121

Data Cards
IMACS System Release 5.1.6
5-7
BRI Card
BRI Card User Screens and Settings
Table 5-2. BRI U*8 and BRI-SC U*8 Card Configuration Option Settings and Defaults
Notes:
1. D-Channels will only show if brite is selected for Type.
2. These options are only available for LB GEN Modes of ddsT and ddsN. See LB GEN
paragraph below.
3. The Sealing Current option setting for the BRI-U*8 (826070) card is n/a and for the
BRI-SC U*8 (826171) card are off and on.
5.3.2
BRI-SC U*8 Sealing Current
This screen applies to the BRI-SC U*8 card only, and only in LT mode. Move the cursor to
the SEAL CURR selection for the desired channel and press
Figure 5-5.
Parameter
User Options
Notes
Default
STATE
stdby actv
stdby
TERMINAL
lt nt
lt
TYPE
lease brite ntu-l
lease
B MODE
none B1 B2 B1+B2 128K
none
B1 WAN/SRV
none w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2 P1 P2 P3
none
B1 TS
n/a 01-24 01-31
n/a
B2 WAN/SRV
none w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2 P1 P2 P3
none
B2 TS
n/a 01 to 24 01 to 31
n/a
D WAN/SRV
n/a w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1
w4-2
1
n/a
D TS
n/a 01 to 24 01 to 31
1
n/a
D SUBCHAN
n/a off 1 2 3 4
1
n/a
LOCAL LB
off ta net
off
LB CHAN
B1 B2 B1+B2
B1
LBGEN MD
ddsT ddsN v54T v54N ft1T ft1N eoc
ddsT
LB GEN
off B1ocu B1csu B1ds0 B1dsu B2ocu B2csu
B2ds0 B2dsu
2
off
SEAL CURR
n/a
off on
3
n/a
TR COND
n/a
n/a