USRobotics V.34 User Manual
Page 158
COURIER HIGH SPEED MODEMS
D-16 Remote Access
Command Format
When typing commands during the remote access session, no
delay between command strings is necessary. For example, you
can type the following commands without pausing after each
one:
•
a password: ABCDEF
•
a configuration string: AT&H1&R2&W
•
and a request for an information screen: ATI5
The maximum number of characters between carriage returns is
40.
Ending a Remote Access Session
One of four commands ends a remote access session.
•
•
ATZ resets the modem and terminates the connection.
•
ATH terminates the connection.
•
ATO or ends the remote access session, but the modems
remain online.
CONFIGURING DIAL SECURITY REMOTELY
The system administrator can configure host Courier security
account information with a Courier modem at a remote site
using the procedures described below.
NOTE: Before remote configuration is possible, the local
modem's remote access must be enabled, and a remote access
password that allows viewing and configuration privileges
must be assigned. For convenience, you may want to use your
local access password as your remote access password.
Dialing In From the Remote Site
1. From the remote site, connect to the host modem using Dial
Security. Once a connection is made, follow the instructions
for beginning a remote access session as described earlier in
this appendix.