beautypg.com

USRobotics V.34 User Manual

Page 121

background image

COURIER HIGH SPEED MODEMS

Summaries and Tables B-27

Register

Default

Function

S53

0

Bit-mapped register. Select the Dial
Security features you want enabled by
setting S53 to the total of the values in the
Value column in the table below. For
example, S53=3, enables Dial Security with
prompting. S53=5 enables Dial Security,
and local-access password protection. Or
use ATS

r.b=0 (OFF) or 1 (ON). For

example, ATS53.0=1 .2=1 turns on bits 0
and 2. To turn a bit off, set that bit to
zero, as in ATS53.2=0.

Bit Value

Result

0

1

Dial security enabled

1

2

Prompting enabled

2

4

Local-access password
protection enabled

NOTE: In addition, enabling local access
password protection disables the &Z

n=s

command which stores up to ten phone
numbers because stored phone numbers
occupy the same space in NVRAM as the
dialback numbers for Dial Security
accounts.

S54

0

Symbol rate bit-mapped register used
primarily by U.S.Robotics Technical
Support for debugging purposes.

Bit 6 (ATS54.6=1) disables Call Indicate
(CI).

Bit 7 (ATS54.7=1) disablesV.8.