beautypg.com

USRobotics V.34 User Manual

Page 154

background image

COURIER HIGH SPEED MODEMS

D-12 Remote Access

AT THE REMOTE MODEM SITE

Remote configuration can be performed at any time during an
asynchronous connection. The user performing remote configu-
ration can use any modem; it does not have to be a U.S.
Robotics model.

1. Make sure the host Courier has been set for remote

configuration, as described earlier. Then establish a
connection. It does not matter which modem originates the
call.

2. After a connection has been established, send the following

escape sequence:

Pause four seconds,
type four tildes: ~~~~
and
pause another four seconds.

NOTE: You can change the escape sequence character
with Register S42. The pause duration (guard time) can be
modified with Register S43. (These values are set at the
host Courier modem.)

3.

When the Courier begins its login sequence, the caller will
see a display similar to the following:

U.S Robotics Courier HST Dual Standard V.34 Fax
Remote Session

Serial Number 000000A000000001

4 . At this point, if password security is active, the caller is

prompted for the password.

Password (Ctrl-C to cancel)?.....

As described earlier in

Password Security, entering the pass-

word assigned by the %P0 command allows viewing
privileges only. Entering the password assigned by the %P1
command allows viewing and configuration privileges.
Note that there is a 3-minute time limit for entering the
password.