COURIER HIGH SPEED MODEMS
Alphabetical Command Summary C-19
%E=4 Erase phone numbers in accounts 0
−
9.
%E=5 Disable Account, Dialback, and New Number fields in
accounts 0
−
9 disabled.
%F
n
Remotely configure data format. See Appendix D.
%F0 No parity, 8 data bits.
%F1 Mark parity, 7 data bits.
%F2 Odd parity, 7 data bits.
%F3 Even parity, 7 data bits.
%L=
Assign an account password as the local access password. See
Appendix D.
%N
Works in conjunction with &X
n in synchronous mode. If the
modem is set so that it is the source of the Transmit clock timing
signals (&X0
default), the %N
n commands set the computer or
terminal-to-modem V.25
bis clock speed. If the modem is set to
&X1, the computer is the source of the Transmit clock signals.
If %N
n is set to 0 or 1, you will receive an error message, since
they are not valid values. The %N
n rates are as follows:
%N0 Reserved
%N6
9600 bps (default)
%N1 Reserved
%N7
12.K bps
%N2 1200 bps
%N8
14.4K bps
%N3 2400 bps
%N9
16.8K bps
%N4 4800 bps
%N10 19.2K bps
%N5 7200 bps
%P
n=
Disables password security
(n=0 or 1) when no character
follows the equal sign. See Appendix D.
%P
n=s
Specify the following password string (
s) for viewing privileges
only (
n = 0) or view and configuration privileges (n= 1). See
Appendix D.
%P
n?
Display password
n. See Appendix D.
%S=
n
Obtain access to security accounts without disabling security.
See Appendix D.