5 Using the KD

5.2.5 Limitations on Stop and Wait Modes

To use stop or wait modes in the User Program, start the KD in free-run mode. If you

want to debug, close the RAM, C Watch and ASM Watch Windows before actually

debugging. Furthermore, set a breakpoint or take other necessary measures when

getting out of stop or wait mode in order to ensure that no window operations will be

performed until the program stops at the breakpoint.

5.2.6 Realtime Capability of the User Program

Please be aware that while the Monitor Program is in its “STOP”ed state, the hardware

peripherals will continue to run. Therefore, interrupts may not be serviced properly. Also,

the watchdog timer will not be serviced and will likely timeout if active.

Note: While the Monitor Program is in its “RUN”ning state, there is no overhead on the

User Program, unless the RAM, C Watch and ASM Watch Windows are open in

KD30/KD3083. These windows require periodic communication with the target

MCU, which suspends normal User Program operation while servicing the

request (approximately 2000 BCLK cycles for each 16 bytes of data displayed in

the window are used per window update). When enabling Realtime Capability in

the User Program, close these windows.