background image

4 Using the FoUSB

5) “PROGRAM” button

This button performs programming to the Target MCU.

(1) Click the “PROGRAM” button, and the screen shown in Figure 4-20 will appear.

Figure 4-20 Program Flash screen

(2) In the Choose an Options section, select either “Erase -> Program -> Verify” or

“Program Only”.

(a) Erase -> Program -> Verify (without lock bit function)

When you select this option, processing is performed in order of Erase, Program and

Verify. A progress bar is displayed, indicating the progress of processing in Erase,

Program and Verify.

(b) Program Only (without lock bit function)

When you select this option, processing is performed for only programming. A progress

bar is displayed, indicating the progress of processing in programming.

Note: The following warning will be displayed if clicking the “Program Only” before

erasing the Target MCU. Clik the button, only when Target MCU is blank

chip.

If the Target MCU is not blank, erase Flash ROM of the Target MCU and

perform the program process.