beautypg.com

Figure 60, High speed flow control configuration, Table 25 – Nortel Networks 1000ASE-XD User Manual

Page 132

background image

132

Chapter 3 Using the console interface

209418-A

Figure 60 High Speed Flow Control Configuration

Table 25

describes the High Speed Flow Control Configuration screen fields.

Table 25 High Speed Flow Control Configuration screen fields

Field

Description

Unit

Allows you to select the unit number (when stacking is configured) to view or
configure. To view or configure another unit, type its unit number and press
[Enter], or press the spacebar to toggle the unit numbers (the system only
displays a screen for units that are configured with a Gigabit MDA).

Autonegotiation

When enabled, the port only advertises support for 1000 Mb/s operation, in
full-duplex mode.

Default Value

Enabled

Range

Enabled, Disabled

Flow Control

Allows you to control traffic and avoid congestion on the Gigabit MDA port. Two
modes are available (see

“Choosing a high speed flow control mode

,” next, for

details about the two modes). The Flow Control field cannot be configured
unless you set the Autonegotiation field value to Disabled.

Default Value

Disabled

Range

Disabled, Symmetric, Asymmetric