Figure 60, High speed flow control configuration, Table 25 – Nortel Networks 1000ASE-XD User Manual
Page 132
132
Chapter 3 Using the console interface
209418-A
Figure 60 High Speed Flow Control Configuration
describes the High Speed Flow Control Configuration screen fields.
Table 25 High Speed Flow Control Configuration screen fields
Field
Description
Unit
Allows you to select the unit number (when stacking is configured) to view or
configure. To view or configure another unit, type its unit number and press
[Enter], or press the spacebar to toggle the unit numbers (the system only
displays a screen for units that are configured with a Gigabit MDA).
Autonegotiation
When enabled, the port only advertises support for 1000 Mb/s operation, in
full-duplex mode.
Default Value
Enabled
Range
Enabled, Disabled
Flow Control
Allows you to control traffic and avoid congestion on the Gigabit MDA port. Two
modes are available (see
“Choosing a high speed flow control mode
,” next, for
details about the two modes). The Flow Control field cannot be configured
unless you set the Autonegotiation field value to Disabled.
Default Value
Disabled
Range
Disabled, Symmetric, Asymmetric