beautypg.com

Paradyne ACCULINK 317x E1 User Manual

Page 93

background image

ACCULINK 317x E1 DSU/CSU

C-6

December 1996

3170-A2-GB20-20

Table C-2

(4 of 4)

Port Configuration Options

Far-end: Disab
Next Disab Maint Prev

Far-End Performance Statistics. Specifies whether to monitor for far-end performance report messages (PRMs) and
maintain far-end performance registers for a particular port.

Disab – Disables far-end performance statistics.

Maint – Monitors the port’s EDL for PRMs and maintains far-end performance statistics.

NOTE: This configuration option is not available and does not appear if

EDL is disabled.

NOTE: If the local E1 DSU/CSU is configured to maintain far-end performance statistics, then the remote E1 DSU/CSU

must be configured to send near-end performance statistics.

Mgmt Link: Disab
Next Disab SNMP Prev

EDL Management Link. Specifies whether the EDL management link is enabled for a particular port. Selecting SNMP
allows SNMP management traffic to flow over the 4 kbps in-band data link provided by EDL.

Disab – Disables the port’s EDL management link.

SNMP – Enables the port’s EDL management link.

NOTE: This configuration option is not available and does not appear if

EDL is disabled or FDL is enabled for SNMP.

NOTE: If the local E1 DSU/CSU’s EDL is enabled, then the remote E1 DSU/CSU’s EDL must also be enabled.