beautypg.com

Setting the ip address – Paradyne ACCULINK 317x E1 User Manual

Page 37

background image

Operation

3-15

3170-A2-GB20-20

December 1996

7. Press F2 to configure the COM port as the

management link to an external SNMP manager.

F1

Com Use:
Next

SNMP

ASCII

F2

F3

Setting the IP Address

The IP address is the address used by the SNMP

manager to access the device. For devices using PPP, the
IP address can be negotiated if the network device (e.g.,
router or SNMP manager) supports such negotiation. The
IP address is composed of four fields with three digits per
field (xxx.xxx.xxx.xxx).

The IP address is set for the COM port or the AUX

port (with LAN Adapter or daisy chain), depending on
which one has been chosen as the SNMP communications
link. The example below assumes that an IP address of
010.155.111.222 is being set for the COM port. You can
use the same principles to assign any value (between 000
and 255 for each digit field) to either port.

To assign an IP address to the COM port,

1. Press F3 to select Cnfig from the top-level menu

screen.

2. Select the configuration option set to be copied

into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.

3. Press F1 to select Edit.

4. Press the

key from the Edit screen to display

the SNMP selection.

5. Select SNMP.

F1

Edit:
User

Alarm SNMP

F2

F3

6. Press F1 to select Gen from the SNMP Config

screen.

F1

SNMP Config:
Gen

Trap

F2

F3

7. Press F1 (Next) until the Com IP Adr

configuration option appears.

NOTE

Steps 8 and 9 describe the
process for entering an IP
address. This process applies to
any IP address.

8. Press F2 (Edit) to edit the IP address. You have the

option of using F3 (Clear) to reset the IP address
to the factory default 000.000.000.000.

F1

Com IP Adr:
Next

Edit

Clear

F2

F3

9. Use the

and

keys to position the cursor

under the digit you want to change. Press F1 (Up)
to increment the digit or F2 (Down) to decrement
the digit. In this example, you would press
once to place the cursor under the middle digit in
the first digit field, then press F1 (Up) once to
change the 0 to a 1. Continue in this manner to
change the other digits.

F1

000.000.000.000
Up

Down

Save

F2