Maintenance

4-23

3170-A2-GB20-20

December 1996

4. From the Patterns Abort screen, press the desired

Function key to abort either All active test
patterns, active Send test patterns, or the active
Monitor (Mon) test pattern.

F1

Patterns: Abort
All

Send

Mon

F2

F3

If you select All, the E1 DSU/CSU terminates all
active test patterns and displays the message
Command Complete. Skip Step 5.

NOTE

Be careful when selecting a specific
test pattern to abort. If you mistakenly
choose to abort a test pattern that is
not currently running, a Command
Complete
message still displays and
the test pattern currently active still
runs. You can use the TStat branch of
the menu to view the test status to
determine if the abort was successful.

5. From the Abort screen, press the Function key that

corresponds to the network or port for which you
want to abort a test pattern. Use the scroll keys, if
necessary.

F1

Abort:

Send or Mon

NET

Prt1

Prt2

F2

F3

The E1 DSU/CSU terminates the selected test
pattern and displays the message Command
Complete
.

Lamp Test

Use the Lamp Test commands to start and stop a test of

the E1 DSU/CSU front panel LCD and LEDs.

Starting a Lamp Test

To start a Lamp test,

1. Press F2 to select Test from the top-level menu

screen.

2. From the Test screen, press

once to display

the Lamp selection on the screen.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Test screen, press F3 to select Lamp.

F1

Test:
Lpbk

Ptrns

Lamp

F2

F3

4. From the Lamp Test screen, press F2 to select

Start.

F1

Lamp Test:
Abort

Start

F2

F3